TQC_Bresle_Patches-328.jpg

TQC Bresle Salt Test Kit


The TQC Bresle Chloride Test Kit includes all the necessary equipment for assessing the level of soluble salts on blast-cleaned surfaces prior to coating.

The Bresle Salt Test Method involves the injection of De-ionized water repeatedly into a Bresle patch affixed to the test surface for 3 - 5 minutes, to dissolve the soluble salts on the surface. The sample is extracted from the Bresle patch and injected into the TQC Conductivity Meter, which will assess and report the conductivity of the test sample, from which the total density of soluble salts is calculated in mg/m2.

The Bresle Kit can also be used to determine the salt contamination of blast-media, to prevent against dissolved salts in the recycled abrasive media or water re-contaminating the cleaned surface.

The TQC Bresle Kit tests for soluble salts including chlorides, sulphates, and nitrates, in accordance with:

  • ISO 8502-6: Preparation Of Steel Substrates Before Application Of Paints And Related Products -- Tests For The Assessment Of Surface Cleanliness - Part 6: Extraction Of Soluble Contaminants For Analysis -- The Bresle Method, and
     
  • ISO 8502-9: Preparation Of Steel Substrates Before Application Of Paints And Related Products -- Tests For The Assessment Of Surface Cleanliness - Part 9: Field Method For The Conductometric Determination Of Water-Soluble Salts.

The TQC Conductivity Meter is water-proof, with an automatic shut-off after about 8 minutes of non-use, and a limited 1-year manufacturer’s warranty against manufacturing defects. The electrode module is warranted against defects for 6 months unless otherwise specified.


The TQC Bresle Chloride Test Kit comes complete with:
 

  • TQC Digital Conductivity meter
  • 25 Bresle Patches
  • distilled water
  • calibration and Cleansing Solutions
  • cups and syringes
  • pictorial manual
  • additional Bresle patches are available in packages of 25

 

KIT SPECIFICATIONS:

Range:                     0,1 – 20.000 mg/m2 (with DSP method)
Resolution:              0,1 mg/m2 (with DSP method)
Accuracy:                1% accuracy of gauge
Temperature range: 0 – 50 °C
ATC:                        0 – 50 °C
Normalization temp: 25 °C
Auto off:                  8.5 minutes after last key pressed
IP class:                   IP67
Auto calibration:     at 84 μS/cm
Patch area:             12,50 cm2
Patch type:             Latex membrane